Chapter 10.Specifications
This section contains specifications for the following:
Overall
Electrical
Transducer
Fluid Types
Pipe Size and Materials
Available Options
10.1 Overall
10.1.1 Hardware Configuration
Channel Options: Single channel
Mode Options: Transit-time
10.1.2 Size/Weight
Size without boot: 238 × 138 × 38 mm
(9.4 × 5.5 × 1.5 inches)
Weight with boot: 1.36 kg (3 lb)
10.1.3 Enclosure
Submersible, IP67
10.1.4 Flow Accuracy (Velocity, % of reading):
Clamp-on Transducers: Pipe Diameter > 150 mm (6 in.)
±1% to 2% of reading typical
Pipe Diameter 150 mm (6 in.)
±2 to 5% of reading typical