GE CRx25P Broszura Strona 37

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 114
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 36
7170
8.2 Film type selection
Most procedures and codes of good practice for the performance of industrial radiography
base the choice of type of film for a specific application on the EN or ASTM classification
systems. For weld inspection, when one is attempting to detect small cracks, a film of class
C2 or C3 would be specified. For the examination of castings or general radiography a film
of class C4 or C5 would normally be used. For small component inspection, where the
image might be viewed under magnification to reveal small details, a film of class C2 or
possibly even a single emulsion film of class C1 would be desirable.
In megavoltage radiography, because most equipment have a very high radiation output,
class C3 films can be used for objects of great wall thickness. This has the advantage that a
high film gradient can be achieved.
8.3 Film sizes
Film sizes in industrial radiography are to a large extent standardised according to
ISO 5565. Non-standard sizes are possible. Standard film sizes and metal screens are
supplied separately, but can also be supplied vacuum-packed so that the risk of film faults
is considerably reduced. For weld inspection there is so-called Rollpac film strip on the
market which is available on a roll together with the lead screen. For very large projects the
strip film can even be pre-cut to suit a particular weld length or pipe/vessel circumference.
8.4 Handling and storage of unexposed films
The conditions under which unexposed films are handled and stored play a very important
role in the final quality of the exposed film. Recommendations for handling and storage
are contained in, for example, ASTM E1254. “Pre-exposure” as a result of background radi-
ation must be avoided as it causes unacceptable fogging of the film.
If films are to be kept for a longer period, the following storage conditions must be
adhered to:
background radiation levels below 90 nGray
temperatures below 24˚C
relative humidity levels below 60 %
away from X-ray film chemicals
preferably stacked on edge
In the long run, minor fogging will occur to films stored. Background fog to a maximum
density of 0.3 is considered acceptable.
Przeglądanie stron 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 113 114

Komentarze do niniejszej Instrukcji

Brak uwag